FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package nictiz.fhir.nl.stu3.zib2015#1.0.0 (109 ms)

Package nictiz.fhir.nl.stu3.zib2015
Type StructureDefinition
Id Id
FHIR Version R3
Source https://simplifier.net/resolve?scope=nictiz.fhir.nl.stu3.zib2015@1.0.0&canonical=http://nictiz.nl/fhir/StructureDefinition/zib-OxygenSaturation
Url http://nictiz.nl/fhir/StructureDefinition/zib-OxygenSaturation
Version 1.0
Status retired
Date 2017-09-06T12:02:17.702+02:00
Name ZIB-OxygenSaturation
Title HCIM OxygenSaturation
Experimental False
Realm nl
Authority hl7
Description This profile is derived from the HL7 Vital Signs profile for oxygen saturation in order to add mappings from the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or ZIB) Lichaamsgewicht and to provide extensions for missing concepts.
Purpose Measuring and monitoring oxygen saturation is done to monitor the oxygenation, or the amount of bound oxygen in the arterial blood.
Copyright CC0
Type Observation
Kind resource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
http://nictiz.nl/fhir/StructureDefinition/oxygensat VitalSigns Oxygensat


Source

{
  "resourceType" : "StructureDefinition",
  "id" : "zib-OxygenSaturation",
  "meta" : {
    "lastUpdated" : "2017-09-08T12:44:22.73+02:00"
  },
  "url" : "http://nictiz.nl/fhir/StructureDefinition/zib-OxygenSaturation",
  "version" : "1.0",
  "name" : "ZIB-OxygenSaturation",
  "title" : "HCIM OxygenSaturation",
  "status" : "retired",
  "date" : "2017-09-06T12:02:17.702+02:00",
  "publisher" : "Nictiz",
  "contact" : [
    {
      "name" : "Nictiz",
      "telecom" : [
        {
          "system" : "email",
          "value" : "info@nictiz.nl",
          "use" : "work"
        }
      ]
    }
  ],
  "description" : "This profile is derived from the HL7 Vital Signs profile for oxygen saturation in order to add mappings from the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or ZIB) Lichaamsgewicht and to provide extensions for missing concepts.",
  "purpose" : "Measuring and monitoring oxygen saturation is done to monitor the oxygenation, or the amount of bound oxygen in the arterial blood.",
  "copyright" : "CC0",
  "fhirVersion" : "3.0.1",
  "mapping" : [
    {
      "identity" : "hcim-o2saturation-v1.2-2015EN",
      "uri" : "https://zibs.nl/wiki/O2Saturation-v1.2(2015EN)",
      "name" : "HCIM O2Saturation-v1.2(2015EN)"
    }
  ],
  "kind" : "resource",
  "abstract" : false,
  "type" : "Observation",
  "baseDefinition" : "http://nictiz.nl/fhir/StructureDefinition/oxygensat",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Observation",
        "path" : "Observation",
        "short" : "Oxygen Saturation",
        "definition" : "This profile defines how to represent Oxygen Saturation observations in FHIR using a standard LOINC code and UCUM units of measure.\r\n\r\nArterial oxygen saturation, also referred to as saturation, is an indicator for the amount of oxygen bound to the hemoglobin in the red blood cells of the arteries. The measurement is usually carried out as a transcutaneous measurement with a blood oxygen monitor or pulse oximeter. The saturation level is expressed as a percentage and should be over 95% in healthy people.",
        "alias" : [
          "O2Saturatie"
        ],
        "mapping" : [
          {
            "identity" : "hcim-o2saturation-v1.2-2015EN",
            "map" : "NL-CM:12.10.1"
          }
        ]
      },
      {
        "id" : "Observation.effective[x]",
        "path" : "Observation.effective[x]",
        "short" : "O2SaturationDateTime",
        "definition" : "The moment (date and time) of the SpO2 measurement.",
        "alias" : [
          "O2SaturatieDatumTijd"
        ],
        "mapping" : [
          {
            "identity" : "hcim-o2saturation-v1.2-2015EN",
            "map" : "NL-CM:12.10.3"
          }
        ]
      },
      {
        "id" : "Observation.valueQuantity:valueQuantity",
        "path" : "Observation.valueQuantity",
        "sliceName" : "valueQuantity",
        "short" : "SpO2Value recorded with UCUM",
        "definition" : "The element contains the value of the indirect, peripheral measured O2 saturation.\r\nThe O2 saturation gives a percentage expressing the extent to which the blood’s hemoglobin is saturated with oxygen, the ratio of oxygen-saturated hemoglobin to hemoglobin. The measurement is done in places where sufficient light can get through the skin, such as a finger, toe or earlobe.",
        "alias" : [
          "SpO2Waarde"
        ],
        "mapping" : [
          {
            "identity" : "hcim-o2saturation-v1.2-2015EN",
            "map" : "NL-CM:12.10.2"
          }
        ]
      },
      {
        "id" : "Observation.comment",
        "path" : "Observation.comment",
        "short" : "Explanation",
        "definition" : "Explanation of the saturation measurement.",
        "alias" : [
          "Toelichting"
        ],
        "mapping" : [
          {
            "identity" : "hcim-o2saturation-v1.2-2015EN",
            "map" : "NL-CM:12.10.4"
          }
        ]
      },
      {
        "id" : "Observation.component",
        "path" : "Observation.component",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "value",
              "path" : "code.coding.code"
            }
          ],
          "rules" : "open"
        }
      },
      {
        "id" : "Observation.component:extraOxygenAdministration",
        "path" : "Observation.component",
        "sliceName" : "extraOxygenAdministration"
      },
      {
        "id" : "Observation.component:extraOxygenAdministration.code.coding",
        "path" : "Observation.component.code.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "value",
              "path" : "code"
            }
          ],
          "rules" : "open"
        }
      },
      {
        "id" : "Observation.component:extraOxygenAdministration.code.coding:ExtraOxygenAdministrationCode",
        "path" : "Observation.component.code.coding",
        "sliceName" : "ExtraOxygenAdministrationCode",
        "max" : "1"
      },
      {
        "id" : "Observation.component:extraOxygenAdministration.code.coding:ExtraOxygenAdministrationCode.system",
        "path" : "Observation.component.code.coding.system",
        "fixedUri" : "http://loinc.org"
      },
      {
        "id" : "Observation.component:extraOxygenAdministration.code.coding:ExtraOxygenAdministrationCode.code",
        "path" : "Observation.component.code.coding.code",
        "fixedCode" : "74206-4"
      },
      {
        "id" : "Observation.component:extraOxygenAdministration.valueCodeableConcept:valueCodeableConcept",
        "path" : "Observation.component.valueCodeableConcept",
        "sliceName" : "valueCodeableConcept",
        "short" : "ExtraOxygenAdministration",
        "definition" : "Indication stating whether the measurement was done in a situation in which extra oxygen was administered.",
        "alias" : [
          "ExtraZuurstofToediening"
        ],
        "type" : [
          {
            "code" : "CodeableConcept"
          }
        ],
        "binding" : {
          "strength" : "required",
          "description" : "Yes/no Indicator",
          "valueSetReference" : {
            "reference" : "http://hl7.org/fhir/v2/0136",
            "display" : "v2 Yes/no Indicator"
          }
        },
        "mapping" : [
          {
            "identity" : "hcim-o2saturation-v1.2-2015EN",
            "map" : "NL-CM:12.10.5"
          }
        ]
      }
    ]
  },
  "text" : {
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.